HQ-M 60KVA-120KVA is the latest industry-leading fully digital uninterruptible power supply product launched by our company. The system adopts a fully modular design, with a capacity configuration of 60-120kVA. It is simple to expand, easy to maintain, and has high cost performance and availability. It is ideal for large and medium-sized data computer rooms. ideal configuration.

ABOUT HQ-M 60-120KVA ONLINE RACKMOUNT MODULAR UPS


Modular UPS can be widely used in postal communications, financial securities, government agencies, energy and chemical industry, transportation, industrial and commercial taxation, medical and health, national defense and military and other electrical equipment that require reliable power supply.


◆FEATURE


scalable ups


Modular design


The cabinet can be configured with up to 7 main power modules; the modular design of the system can be designed according to future system needs, and the modules can be configured according to the existing load, significantly reducing one-time investment costs.


data center ups

High Reliability

*Distributed control system for power module

*Isolated air duct for key components

*BMS monitors battery information in real time

*Online UPS: online double conversion

power supply module

Green Performance

*Efficiency up to 96%

*Output PF = 1

*Maintenance bypass mode

*THDi < 3% and input PF > 0.99


◆OTHER


Modular UPS Systems

Offering scalability for easy expansion or reduction of capacity

Rackmount UPS

Rack-mountable for optimized space efficiency

20kVA UPS

Capacity: 40kVA/50kVA/80kVA/100kVA/120kVA/150kVA

Online UPS

Topology: online double conversion




Specification

ModelHQ-M60HQ-M75HQ-M80HQ-M100HQ-M120
Capacity60kVA75kVA80kVA100kVA120kVA
Cabinet Type4 Modules7 Modules
Power Module Capacity10/15/20kVA25kVA10/15/20kVA25kVA10/15/20kVA
Input
Rated Voltage3 Phase+N+PE 380/400/415VAC(Line voltage)
Rated Frequency50/60Hz
Voltage Range (Full Load)304478VAC
Frequency Range40 ~ 70Hz
Power Factor>0.99
THDi3%(100% linear load);< 5%(100% non-linear load
Bypass
Rated Voltage380/400/415VAC(Line voltage)
Voltage RangeDefault: -20%  +15%configurable, upper limit: +10%, +15%, +20%, +25%lower limit: -10%, -15%, -20%, -30%, -40%
Battery
Voltage±192VDC(±180 ~ ±264VDC, 30 - 44 units configurable, default: 32 units)
Output
Rated Voltage380V/400V/415V(Line voltage)
Rated Frequency50/60Hz
Power Factor1
Voltage Accuracy≤±1.0% @ balanced load ≤±5.0% @ unbalanced load
Frequency Accuracy50/60Hz ± 0.1%
Frequency Tracking Range±0.5Hz ~ ±5Hz, configurable, default: ±3Hz
THDu≤2%(100% linear load), ≤4%(nonlinear load)
Three-Phase Accuracy120° ± 
Crest Factor3:01
Overload105%, long run 105% ~ 110%, 60min 110  125%, 10min125 150%, 1min 150%, switch to the bypass immediately
System
Efficiency96%
Display7” Touch screen + LED
StandardIEC62040-1-1; IEC62040-2; IEC62040-3
OptionalLightning protection module, dustproof net, load break switch cable, seismic kit
Protection ClassIP20
CommunicationRS232/ RS485, optional: SNMP/dry contact
Operating Temperature0 ~ 40°C
Humidity0 ~ 95%(Non-condensing)
Altitude1000M no derate, 1000m derate 1% per 100m
Noise<65dB @ 1m
Size
System W x D x H(mm)600 x 850 x 1200
Module W x D x H(mm)440 x 690 x 86(2U)
Weight
System(kg145210
Module(kg20(10kVA), 22(15kVA), 24(20kVA), 25(25kVA)