ABOUT DTH11-R SINGLE PHASE ONLINE RACK UPS
Applications: LAN server, communication base station, data center, finance system branch, automation control system, etc.
◆FEATURE
Advanced Technology
*110~300VAC input range
*50/60Hz Auto-sensing
*Generator compatible
*1 phase UPS, 1 phase input, 1 phase output
*Double conversion online design
Outstanding Flexibility
*6/10kVA: 16-20 battery units (configurable)
*Support RS232, USB, optional: RS485, dry contact, SNMP
*Compact, rack mount UPS
*Versatile and adaptable, suited for use as a server rack UPS
Green Performance
*ECO mode included
*PFC technology
*Input PF ≥ 0.99
*Output power = 1
*Automated fan speed configuration
◆OTHER
Rack mount design, enhances the space efficiency
Single Phase Input, Single Phase Output
Capacity: 1kVA/2kVA/3kVA/6kVA/10kVA
Online double conversion technology
Ideal for deployment in LAN servers and various other server applications
Specification
Model | DTH11-1K | DTH11-1KL | DTH11-2K | DTH11-2KL | DTH11-3K | DTH11-3KL | DTH11-6K | DTH11-6KL | DTH11-10K | DTH11-10KL | |||||||||||||
Capacity | 1kVA | 2kVA | 3kVA | 6kVA | 10kVA | ||||||||||||||||||
Input | |||||||||||||||||||||||
Voltage Range | 1 Phase (L+N+PE)110 ~300VAC | ||||||||||||||||||||||
Frequency Range | 40Hz ~ 70Hz | ||||||||||||||||||||||
Power Factor | ≥0.99 | ||||||||||||||||||||||
THDi | <3% (100% linear load) ; <5% (100% nonlinear load) | ||||||||||||||||||||||
Output | |||||||||||||||||||||||
Voltage | 208/220/230/240VAC | ||||||||||||||||||||||
Voltage Accuracy | ±1% | ||||||||||||||||||||||
Frequency Range | 50/60Hz ± 0.1% | ||||||||||||||||||||||
Overload | 102%~110%, 30min; 111%~130%, 10min; 131%~150%, 30sec; >150%, 0.2sec | ||||||||||||||||||||||
Power Factor | 1 | ||||||||||||||||||||||
THDu | ≤2% @ (100% linear load) ;≤5% @ (100% nonlinear load) | ||||||||||||||||||||||
Switching Time | 0 ms | ||||||||||||||||||||||
Efficiency | |||||||||||||||||||||||
Inverter Mode | 94.5% | >95.5% | |||||||||||||||||||||
Battery | |||||||||||||||||||||||
Standard | Model | 12V / 7Ah | |||||||||||||||||||||
Number | 2 | 4 | 6 | 16 | |||||||||||||||||||
Charging Current | 1A | 1-4A Configurable(default 1A) | |||||||||||||||||||||
Rated Voltage | 24V | 48V | 72V | 192V | |||||||||||||||||||
Long Backup | Number | 3 | 6 | 8 | 16-20 | ||||||||||||||||||
Charging Current | 1-12A Configurable(default 5A) | ||||||||||||||||||||||
Voltage | 36VDC | 72VDC | 96VDC | 192-240VDC | |||||||||||||||||||
System | |||||||||||||||||||||||
Communication | RS232, USB, optional: RS485, dry contact, SNMP | ||||||||||||||||||||||
Environment | |||||||||||||||||||||||
Operating Temperature | 0 ~ 40°C | ||||||||||||||||||||||
Humidity | 0 ~ 95%(Non-condensing) | ||||||||||||||||||||||
Altitude | <1000m no derate, >1000m derate(refer to IEC62040) | ||||||||||||||||||||||
Noise | < 50dB @ 1 m | ||||||||||||||||||||||
Physical | |||||||||||||||||||||||
Standard | W×D×H(mm) | 145×276×225 | 145×392×225 | 190×395×325 | 190×400×700 | ||||||||||||||||||
Weight(kg) | 8.2 | 15.3 | 20.5 | 47.2 | 48.5 | ||||||||||||||||||
Long Backup | WxDxH(mm) | 145x276x225 | 145x392x225 | 190x400x330 | |||||||||||||||||||
Weight(kg) | 3.7 | 5.5 | 6.0 | 8.8 | 9.6 | ||||||||||||||||||
* Specifications subject to change without notice. |