eLite Pro Solar Energy Hybrid Inverter
eLite Pro Seires works with solar panels and batteries to form an energy storage system. Featuring backup mode to ensure the stable power supply when utility failed
eLite Pro Seires works with solar panels and batteries to form an energy storage system. Featuring backup mode to ensure the stable power supply when utility failed
The 3-5kW single-phase off grid inverter is an all-in-one system for supplying solar power at home. It can be flexibly configured to single-phase or three-phase
Application: Computer, data center, telecom, finance, security, transportation, medical, petrochemical, etc.
ABOUT DTH31 3 PHASE IN 1 PHASE OUT ONLINE UPS
The EVADA DTH31 3 Phase In 1 Phase Out Online UPS, an exceptional 3 Phase In 1 Phase Out Online UPS with unit power supply capabilities. This high performance UPS, featuring a 3 Phase In 1 Phase Out configuration, it's perfect for diverse applications. It’s a UPS with external batteries and also a UPS with wheels, it guarantees not just dependable power but also effortless mobility.
◆FEATURE
Advanced Technology
*Input range: 110~300VAC
*50/60Hz Auto-sensing
*N+X parallel technology
*Automated self-testing
*Generator compatible
*3 Phase in 1 phase out
Outstanding Flexibility
*Battery numbers configurable
*Multifunction LCD&LED readout
*Mains power start
*Cold start function
*Adjustable input: 3 phase 380V or 1 phase 220V
*UPS with wheels
*UPS with external batteries
Green Performance
*ECO mode for energy saving
*Power Factor Correction Technology
*Input pf ≥0.99 at 100% load
*Support RS232, USB, optional: RS485, dry contact or SNMP
◆OTHER
Battery number: 16~20 units configurable
Three Phase Input, Single Phase Output
Inverter mode operates with an efficiency ranging from 92% to 93%
Allowing convenient relocation and flexibility in adapting to dynamic operational requirements
SPECIFICATION
Model | DTH31-10KL | DTH31-15KL | DTH31-20KL |
Capacity | 10kVA | 15kVA | 20kVA |
Input | |||
Rated Voltage | 380VAC 3 Phase+N | ||
Voltage Range | 110~300VAC | ||
Frequency Range | 46Hz~54Hz @ 50Hz system; 56Hz~64Hz @ 60Hz system | ||
Power Factor | ≥0.99 @ 100% load | ||
THDi | <3% (100% linear load); <5% (100% nonlinear load) | ||
Output | |||
Voltage | 208/220/230/240VAC | ||
Voltage Accuracy | ±1% | ||
Frequency Range | SynchronizationRange: 46Hz~54Hz @ 50Hz or 56Hz~64Hz Battery Mode: 50Hz ± 0.1Hz or 60Hz ± 0.1Hz | ||
Mains Power | 100%~110%, 10min; 110%~130%, 1min; >130%, 1sec | ||
Battery Mode | 100%~110%, 30sec; 110%~130%, 10sec; >130%, 1sec | ||
Power Factor | 0.8 (optional 0.9) | ||
THDu | ≤2% @ (100% linear load);≤5% @ (100% nonlinear load) | ||
Crest Factor | 3:1 | ||
Switching Time | 0ms | ||
Efficiency | |||
Inverter Mode | 92% | 93% |